BIOMA

bioma - software for balance method (vers. 2.2.1304)

BIOMA allows determination of the following parameters of
Waste-to-Energy plants:

• ratio of energy produced from biogenic sources

• carbon dioxide originating from fossil sources

• lower/upper heating value of the waste feed

• carbon content of the waste feed

• content of biomass (ash and moisture free) of the waste feed

• content of fossil matter (ash and moisture free) of the waste feed

• ash content of the waste feed

• water content of the waste feed

 

Only is routinely measured operating data of the Waste-to-Energy plant are required. Detailed information regarding the input data required can be found in the info folder.

 

BIOMA offers:

• automatic data processing and reporting (annual reports)

• online calculation (1 hour resolution)

 

Download a free trial version (including user manual). No data base installation necessary. Restriction of trial version:

• no import of operating data and report packages possible

• all changes will be reset when BIOMA is closed

 

If you are interested in a licensed version of BIOMA please contact:

Christian Riber
Business Development Manager

Ramboll Group A/S
Waste-to-Energy

DK-2300 Copenhagen S, Hannemanns Allé 53
Denmark

Phone: +45 5161 8314
E-Mail: CTR@ramboll.com

BIOMA Software - Ramboll Group

 

or

 

Univ.Prof. Dr. techn. Helmut Rechberger

Vienna University of Technology
Institute for Water Quality, Resources and Waste Management

A-1040 Vienna, Karlsplatz 13/226
Austria

Phone: +43-1-58801-22645
E-Mail: helmut.rechberger@tuwien.ac.at

http://iwr.tuwien.ac.at/ressourcen

 

Legal Information:

Vienna University of Technolgy is proprietor of a patent application titled „Verfahren zur Ermittlung der Anteile biogener und fossiler Energietraeger sowie biogener und fossiler Kohlendioxidemissionen beim Betrieb von Verbrennungsanlagen“ (Method to determine the fraction of biogenic and fossil energy carriers as well as biogenic and fossil carbon dioxide emissions at the operation of combustion plants). The European Patent Application number is published under no. EP 1715339.

Vienna University of Technology will prosecute any infringement of the mentioned patent becoming known to us.

 

___________________________________________________________________________

Developed by:

Institute for Water Quality, Resources and Waste Management & inka software

___________________________________________________________________________

 

Relevant scientific publications:

J. Fellner, O. Cencic, H. Rechberger: "A New Method to Determine the Ratio of Electricity Production from Fossil and Biogenic Sources in Waste-to-Energy Plants"; Environmental Science and Technology, 41 (2007), 7; S. 2579 - 2586.

http://pubs.acs.org/

 

J. Mohn, S. Szidat, J. Fellner, H. Rechberger, R. Quartier, B. Buchmann, L. Emmenegger: "Determination of biogenic and fossil CO2 emitted by waste incineration based on 14CO2 and mass balances"; Bioresource Technology, 99 (2008), S. 6471 – 6479.

http://www.sciencedirect.com/

 

J. Fellner, O. Cencic, Zellinger, G., H. Rechberger: "Long term analysis of the biomass content in the feed of a waste-to-energy plant”; Waste Management & Research (2011), doi: 10.1177/0734242X10394913

http://wmr.sagepub.com/

 

M. Obermoser, J. Fellner, H. Rechberger:

"Determination of reliable CO2 emission factors for waste-to-energy plants";

Waste Management & Research, 27 (2009), 9; S. 907 - 913.

http://wmr.sagepub.com/

 

W. Staber, S. Flamme, J. Fellner: "Methods for determining the biomass content of waste"; Waste Management & Research, 26 (2008), 1; S. 78 - 87.

http://wmr.sagepub.com/